Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the redux-framework domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the workreap domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the customized-task-offer domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the workreap-hourly-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/runcloud/webapps/uplancer/wp-includes/functions.php on line 6131
STMicroelectronics 5V Controller

STMicroelectronics 5V Controller

★★★★★ 4.4 74 reviews

$90.00
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by uplancer.com
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
$90.00
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Apr 26
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by uplancer.com
Free 30-day returns Details

Product details

Management number 213649527 Release Date 2026/04/12 List Price $36.00 Model Number 213649527
Category

The STM6600-01 devices oversee connected push-button states and adequate supply voltage. An enable output manages power for the application via a MOSFET transistor, DC-DC converter, regulator, etc. If the supply voltage surpasses a precise threshold, the enable output can be activated by simply pressing the button. Factory-selectable voltage thresholds are set by highly accurate, temperature-compensated references. An interrupt is triggered by pressing the push-button during normal operation, allowing for a system power-down request. The interrupt also activates if undervoltage is detected. A long push of one or two buttons either asserts a reset or disables power for the application, depending on the chosen option.

  • Voltage Range: 1.6 V to 5.5 V
  • Low Power Consumption: 0.6 μA in Standby
  • Adjustable Reset Delay: Driven by External C SRD
  • Power-Up Duration: Determined by Push-Button Press or Fixed Time
  • Input Signals: Debounced PB and SR
  • ESD Protection: Up to ±15 kV (Air) and ±8 kV (Contact)
  • Enable Output: Active High or Low, Controls MOSFET, DC-DC, etc
  • Startup Security: Interrupt, Smart Reset, or Power-Down via Push-Button
  • Voltage Reference: Precise 1.5 V with 1% Accuracy
  • Operating Range: Industrial Temperature –40 to +85 °C
  • Package Size: TDFN12 2 x 3 mm
Brand Name STMicroelectronics

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.4 out of 5
★★★★★
74 ratings | 30 reviews
How item rating is calculated
View all reviews
5 stars
81% (60)
4 stars
5% (4)
3 stars
2% (1)
2 stars
1% (1)
1 star
11% (8)
Sort by

There are currently no written reviews for this product.